(Details Inside), Press J to jump to the feed. You should be able to check from the Solar edge portal: - Charts - Inverter - AC Voltage. My co-worker got his replaced in 4 days they do 2 day shipping but if your installer waits then that is another story. Ground faults may occur due to insufficient insulation to the ground. Your email address will not be published. On my Solaredge 7600 HD inverter, I found recorded " Error Code: 181 Internal error" listed on the monitoring website every day since March 4th sometimes several recordings on the same day. Guy said it was a bad sensor. Yeah, the first part of the error code 18xB5 is associated with hardware failures in a couple places I've found. ELECTRICAL HAZARD. Does anyone have any insight on their monitoring process? Well. Update. Verify that proper clearances exist around the inverter. 30. Make use of the SolarEdge Support Center for US - Get free professional resources and additional information, chat with our representatives, and more. 2. Just like restarting your computer, restarting your inverter can fix some common issues. Error code - 11 Error code - 40 Error code - 2xE Error code - 152 Error code - 8x10 Vote THIS. Every service call is two months. CPU v3.18xx and below - Error Code - 176 CPU v3.19xx and above - Error Code - 3x6A Error Message: For info contact your installer Solutions: Inverter remotely locked . Just like restarting your computer, restarting your inverter can fix some common issues. Put me on group call with titan solar who said earliest they can get out is next Friday. I can't imagine 5 days of almost zero production and associated error codes not meeting their "everythings okay" standard? Sorry you're having trouble. Reason I was asking was because the SolarEdge support while helpful, didn't say much other than they would pass it on to engineering. It would crap out around 7.5kW and then go off and on most of the day. Get refined data-driven product insights as they launch. http://www.solaredge.com/files/pdfs/application-note-recommended-wiring.pdf, http://www.solaredge.com/files/pdfs/phase_balancing_connection_guide.pdf, Faults and errors that are displayed on the inverter (take note of these before restarting your inverter in case the error continues). Emailed yesterday morning. A certified installer must fix the faulty string before connecting it to the inverter. CPU v3.19xx and later, inlcuding 4.x CPU v3.18xx and before CPU v3.19xx and later, including 4.x 16, 149, 153, 181, 166-168, 170 Sungrow Alarm Codes; Consider This Your Ultimate Guide! By using our website, mobile applications, or any of our online products and services (Services), you consent that we can access, collect, store and use cookies and your IP address in accordance with our Cookies Policy. 30. Below is a list of the various codes that may appear on your SolarEdge inverter. Check with the grid operator if a large surge source or irregular load exists near the site. Discussion of solar photovoltaic systems, modules, the solar energy business, solar power production, utility-scale, commercial rooftop, residential, off-grid systems and more. Inverter Status and System Performance Indications Your inverter has a switch and three colored LEDs that indicate system information, such as errors or performance. This is located either above the black dial/DC disconnect or on the left side in the back of your inverter. The inverter has shut off due to islanding. When offline, the PV panels produce their Open Circuit voltage, which can be about 20% higher than max power voltage, and so you see the high DC voltage. While it was happened I saw on the Inverter that there was an overheating fault but both fans were working. Firmware-update-before-all-else (like old Windows support days of reboot your computer) is SolarEdge's goto protocol for probably everything, at least that's what it seems from folks sharing their stories. System has been running for almost a year. And then today just got an email with RMA and estimated 5 days until shipped. If the fault persists, contact SolarEdge support or your solar provider. Let me clear. Sorry we couldn't be helpful. I'm familiar with that code. If the inverter is located far from the connection point to the grid, use a larger gauge AC wire. Only a certified PV installer must fix the. If you look at the spec sheet below the SE7600H can handle a DC input up to 11800W and the SE3000H can handle a DC input up to 4650W. RIP my solar power system. Error code - 4, 5, 6, 8, 11, 12, 18, 22, 42, 45, 48, Error code - 16, 149, 153, 181, 166-168, 170, Error code - 2x13, 2x15, 2x16, 3x2, 2x2D, 3xC, 3xF, Error code - 2x10, 2x95, 2x59, 2xB5, 18xA6-A8, 18xAA, Error code - 3x11, 2x96, 2x97,18xC, 18x8E, Error code - 45, 48, 94, 107- 111,113, 132-134, 140, Error code - 95, 106, 125,126, 161, 162, 166, 172-175, Error Code - 3x2, 3xC, 3xF, 8x11 - 8x13, 8x3D, 8x4A - 8x4E, 8x50, Error Code - 8x3E, 8x49, 8x5C, 8x5D, 8x75-79, 8x7A- 7F, 8x80-83, Error Code - 8x1C/ 8x1D/ 8x1E 8x22/8x23/8x24, Error Code - 8x3A/8x3B/ 8x3C 8x3F/ 8x40/ 8x41. The following tables detail the possible LED and switch combinations, and what they mean. overvoltage is detected, the inverter shuts. 2. M. AC is connected but the system is not producing. Switch between L1 and L2 or L2 and L3 connections. Wait 5 minutes for the capacitors to discharge. read your contract with them closely and see what it means to you. The inverter is not configured to any country. Join. Sorry we couldn't be helpful. Make sure that the heat-sink fins are clear of first and obstacles. faulty string before connecting it to the inverter. Solutions: PV Isolation fault. Welcome to the misery that is solaredge. you should have your installer deal with the hassle, you paid them for it and this should be covered service. When your panels kick in and start cranking power, the grid voltage goes high and they trip offline. This video will guide you through how to troubleshoot a 3x6E when there is no meter installed on the Site. Called them. These common issues include: Report: Sunpower Maxeon Performance 3 Series. Pick a date range that coincides with the day you were having issues - interestingly, I had super low grid voltage yesterday - around 216V at the time the inverter started playing up (around 4pm), and down as low as 204V at 7pm last night Record the number (or numbers) displayed on the inverter and note if the inverter is single or three-phase (important). Be ready for the storm with Weather Guard, Three Phase Inverters with Synergy Technology, StorEdge Products for On-Grid and Backup Applications, Inverter is communicating with the monitoring platform. Also, aren't they supposed to be monitoring our system? 8kW Synergy Inverter Data Sheet (PDF) SolarEdge Optimiser. We recommend restarting your inverter if any issues do arise. Add a Comment. You got a dead Inverter and will need to be replaced. By accepting all cookies, you agree to our use of cookies to deliver and maintain our services and site, improve the quality of Reddit, personalize Reddit content and advertising, and measure the effectiveness of advertising. One thing I'd like to point out is that my inverter has been running what I suspect rather hot. If the problem persists, consult with the grid operator whether frequent AC disruptions have occurred at the site. Get refined data-driven product insights as they launch. Be very careful, don't try to hook a meter up to 400VDC, one tiny mistake and you are toast. If after five minutes, the LCD panel does not show a low safety voltage (1V per optimizer), check which string is malfunctioning, and recheck its connections to the inverter. How efficient will it become? Hopefully it's just the out-of-the-box mortality failure and the replacement gets you smooth sailing. The SolarEdge inverters can actually be powered by panels that are about 50% over the inverters output rating. This email is to inform you that we have identified your solar system needs service. ALL RIGHTS RESERVED. These may relate to external factors like grid voltage or wiring, The system not communicating with internet monitoring (you may also need to restart your modem), If the system is generally not performing as it should. Went out to setup and noticed fault light and error code. Being net-zero is awesome. Jump to the relevant SolarEdge inverter error code selection using one of the buttons below. The AC relay failed during wake-up tests. 2) If your inverter has a screen, wait until the DC voltage reading goes below 50 VDC. As long as they aren't in danger of not meeting the performance guarantee and having to pay for the lost production, they will put you at the bottom of the repair queue. Error#SinglePhase Inverter Error#ThreePhase Inverter LCD Message CauseandTroubleshooting CPUv3.18xx andbefore CPUv3.19xx andlater CPUv3.18xx andbefore CPUv3.19xx SolarEdge is using cookies to improve your user experience. We recommend restarting your inverter if any issues do arise. Case for blocking A 1970 built Catholic church achieves a self-sufficiency You can see here my Hyundai Kona EV being charged by the sun. Solar Edge inverter error codes System has been running for almost a year. Grid frequency is below the limit permitted. Broken or unconnected Temperature Sensor. But our SCADA monitoring analyses say otherwise and indicate a 1/3 drop in production of the inverter. Turn OFF the inverters in the site and verify AC grid voltage. Wouldn't surprise me that if you were to open up the top cover, there are some burnt up components. If permitted by local authorities, use theSolarEdge Configuration Tool to change the settings. GEM Energy support 1300 969 471. Decipher All Ginlong/ Solis Alarm Codes With Ease. so we got solar panels on Wednesday My journey from planing to PTO (10/24) completed now. Was a pain in the ass to unmount it and mount it again but we're back up and . Yesterday, generation ceased. VLL Max or V-Line Max This error code indicates that the inverter is measuring a high voltage of a grid to the parameters that the device has been set to an operating point. When will it become so affordable that it's accessible to everyone? The isolation is checked each time the inverter starts up. Do not connect strings with a grounding fault to the inverter. Dispatch had gone home already so she said someone "should def call you within 2-4 days to setup an appt". Report: Sunpower Maxeon Performance 3 Series. unfortunately if this is a leased system they don't have a huge incentive to fix it quickly. Are you experiencing this error on your Solaredge Inverter?Error code 18x86Isolation FaultSee diagnostic menuWatch this video to see how I troubleshoot and f. Change the Phase Balance option in theInverter's LCD menu to Disable.Refer to Power Control on page 35 and to the SolarEdge Phase Balancing Manual, available on the SolarEdge website at http://www.solaredge.com/files/pdfs/phase_balancing_connection_guide.pdf. Is that the standard response time? Last time they came out (last fall after install, inverter failed intermittently on startup), couldn't do anything because it wasn't broken that second (not like this issue) and I had to start all over again. #1 9.75 kWp system - 30 x LG Neon 2's, SolarEdge Inverter, Optimisers, 2 x Powerwall2's - is coming up 3 years old. All breakers and switches in correct position. The tech will check all voltages, determine it is dead, call Solaredge, get an RMA processed and a new one will be sent out. Below is a list of the various codes that may appear on your SolarEdge inverter. The internal hardware that measures ground fault has measured substantially high ground currents. Your inverter has a switch and three colored LEDs that indicate system information, such as errors or performance. r/solar. How to power cycle a SolarEdge inverter: 1) Flip the red switch into the off "0" position. Check the PV installation for isolation problems and ground leakage. Only a certified PV installer must fix the faulty string before connecting it to the inverter. It Day 1 Install Underway!!! Tried rebooting system but error code '18 x B7 - HW Error' keeps reappearing. Turn the inverter OFF and then ON. By rejecting non-essential cookies, Reddit may still use certain cookies to ensure the proper functionality of our platform. Verify that the output wire size matches the distance between the inverter and the location of the grid connection. The monitoring hardware that checks the balance of each phase (L1-N and L-2-N) has exceeded the allowed limit. Ground current surge. For further documentation about possible ground current error sources and solutions contact SolarEdge support. Grid frequency is above the limit permitted. Normally check output each day thru Mysunrun site. I'm going to be down for at least a week and a half before someone even gets out here. Once our Technician resolves the service request, we will provide a follow up email detailing the resolution as well as a survey to gather feedback on your visit. DC overvoltage.The input DC voltage exceeds the maximum supported level. Solar series parallel charging oddity. Help us improve this article with your feedback. Dont know why but I figured they would call in the 5 business days as they said but of course they didnt. Any combination of LEDs on condition that the blue LED is on. They need to come out and who knows then how long it will take to replace, repair, whatever. Then in the evening it would resume working as normal. If the fault persists, contact SolarEdge support or your solar provider. Grid voltage is below the limit permitted. In the event that restarting your inverter doesnt work, here is a list of what to do in the event of each SolarEdge status code. What SolarEdge inverter error codes are you experiencing? Normally check output each day thru Mysunrun site. MisterSandals Participation Medalist Joined Nov 5, 2019 Messages 6,367 Location Silicon Valley Aug 21, 2021 #2 About Codes >Solaredge Error Inverter. Only a qualified electrician should handle this problem and only after taking proper precautions. RMA turnaround times on SE stuff is closer to 6-8 weeks just to get the eqpt. If your inverter does not have a screen, wait for 5 minutes. It if persists, you can consult SolarEdge customer service to check whether the problem is with the inverter or grid. Emailed yesterday morning. Main Indications System Performance Information AC Output Power Production Percentage The following tables detail the possible LED and switch combinations, and what they mean. Any combination of LEDs on condition that the green LED is on. Help us improve this article with your feedback. Good luck getting a replacement within 10 business days. BIG! Refer to the AC Wiring Application Note, available on the SolarEdge website at. Contact . SE claims this is a comms issue and not a production issue. Any combination of LEDs on condition that the red LED is on. CPU v3.18xx and below - Error Code - 123 CPU v3.19xx and above - Error Code - 18x7B Error Message: Main Error Solutions: Grid measurements are out of range. If the fault persists, contact SolarEdge support or your solar provider. (uuru 6lqjoh 3kdvh (uuru 7kuhh 3kdvh /&' 0hvvdjh 'hvfulswlrq 7urxeohvkrrwlqj $& 9rowdjh 7rr +ljk /lqh $& yrowdjh vxujh 7khlqwhuqdokdugzduhwkdw phdvxuhv $& yrowdjh kdv phdvxuhg vxevwdqwldoo\ kljk The inverter has detected the PV solar array is not properly isolated from ground earth. Reddit and its partners use cookies and similar technologies to provide you with a better experience. The RCD measurement has failed during the wake-up test phase. No response so called just now and she walked me through a full shutdown and restarted with same errors. Grid voltage is above the limit permitted. The input DC voltage is below the minimum level that is supported. Proceed according to Power Optimizers Troubleshooting on page 57, Re-commission all inverters in the site, as described in Chapter 4: Commissioning the installation. Check the L1, L2 and Neutral wire connections. Solar photovoltaic technology is one of the great developments of the modern age. Best. Contact SolarEdge support or your Solar provider. Finally contacted back by MySunrun. Do I have any recourse for any of this? ALL RIGHTS RESERVED. Got home from work trip and noticed 3 days of 1 kwh followed by a 5 kwh day and then 0. 7 megs banked going into My net-zero all-electric home in Maryland. House built in the 60s with the meter and panel recessed finally solar! Diagnose your respective SolarEdge error codes in these 3 easy steps; 1. How are other energy industries having an effect on solar pv? Edit: Follow-up on your other question, yes they're monitoring, but it's not as near as daily or any type of efficient automated system, they might dispatch a tech if you don't produce for a week. Improvements to design and cost reductions continue to take place. If the fault persists, reinstall the inverter in a warmer place. 13. Original subscribers (that's you) receive price protection, granular product insights and early access content. A Certified Technician from P. M. & M. Electric, Inc. will be contacting you in the next 5 business days to coordinate an appointment to service your system. All of the SolarEdge inverter status codes, meanings and solutions. V-Line Min or VLL Min Become an Original Subscriber. IS. Verify that the inverter is set to the correct country. Went out to setup and noticed fault light and error code. Verify that AC to the inverter is OFF, or disconnect the AC to the inverter by turning OFF the circuit breakers on the distribution panel. Press question mark to learn the rest of the keyboard shortcuts. If you do not hear from anyone within this timeframe, please feel free to contact us at 1-855-478-6786. When AC voltage returns, the inverter should restart after the reconnection time, which depends on country grid connection codes. Do not touch insulated wires when the inverter cover is removed. Had this exact same error code and it took about 6 weeks (assuming you're with sunrun) to get the inverter replaced. However, energy production has been good. Got home from work trip and noticed 3 days of 1 kwh followed by a 5 kwh day and then 0. Hopefully it doesnt need to be replaced or your system will be down for a lot more than just a week or 2. Consult the grid operator. Be appreciated. Some really dumb stuff to check while waiting: All solar related breaker switches in main panel still OK. Will inverter work w/o the battery (turn off main battery breaker)? AC grid voltage is out of range. System has been completely powered down twice now. Use a larger gauge wire for the AC output. voltage or a switching load near the site.